Product Description
The test system is designed to evaluate the electrical performance of solid oxide fuel cells and stacks. It features gas‑line control, data acquisition, intelligent temperature regulation, and fuel‑gas leak‑detection safety alarms, enabling real-time monitoring of performance under various operating modes, including constant current, constant voltage, and constant power.
Key product features:
● Equipped with multiple gas supply and humidification modules to simulate various fuel‑type testing requirements.
● Customized test plans tailored to customer requirements, along with SOFC/SOEC testing skills training.
● High measurement and control accuracy, with test data management capabilities.
| Test System Parameters | ||||||||||||||||||||||
| Device model | HBSOC-100 | HBSOC-500 | HBSOC-1000 | HBSOC-2000 | HBSOC-5000 | Note | ||||||||||||||||
| Test power | 100 W | 500 W | 1 kW | 2 kW | 5 kW | |||||||||||||||||
| Cathode gas type | Air | Air | Air | Air | Air | |||||||||||||||||
| Cathode gas flow rate (SLM) | 0.2-20 | 0.5-50 | 1-100 | 2-200 | 5-450 | |||||||||||||||||
| Cathode gas control accuracy | ±1%F.S | ±1%FS | ±1%FS | ±1%FS | ±1%FS | |||||||||||||||||
| Anode gas type | H₂ | CH₄ | CO | Carbon dioxide | N₂ | H₂ | CH₄ | CO | Carbon dioxide | N₂ | H₂ | CO | Carbon dioxide | N₂ | H₂ | Carbon dioxide | N₂ | H₂ | Carbon dioxide | N₂ | Anode gas type Customizable | |
| Anode gas flow rate (SLM) | 0.1-5 | 0.1-2 | 0.1-5 | 0.1-5 | 00-5 | 0.2-20 | 00-5 | 0.2-20 | 00-5 | 0.2-20 | 0.2-20 | 0.2-20 | 0.2-20 | 0.2-20 | 0.5-50 | 0.5-50 | 0.2-20 | 2-150 | 0.5-50 | 0.5-50 | ||
| Anode gas control accuracy | ±1%F.S | ±1%FS | ±1%F.S | ±1%FS | ±1%FS | |||||||||||||||||
| Gasification water flow rate (SCCM) | 00-5 | 00-5 | 0-20 | 0-50 | 0-50 | |||||||||||||||||
| Steam control accuracy | ±1% | ±1% | ±1% | ±1% | ±1% | |||||||||||||||||
| Steam outlet temperature (°C) | 200-280 | 200-280 | 200-280 | 200-280 | 200-280 | |||||||||||||||||
| Discharge Module (SOFC) | Discharge Voltage (V) | 0-120 | 0-120 | 0-120 | 0-150 | 0-150 | ||||||||||||||||
| Discharge current (A) | 0-120 | 0-120 | 0-240 | 0-200 | 0-600 | |||||||||||||||||
| Electrolysis Module (SOEC) | Electrolysis voltage (V) | 0-32 | 0-80 | 0-160 | 0-80 | 0-300 | ||||||||||||||||
| Electrolytic current (A) | 0-110 | 0-40 | 0-40 | 0-150 | 0-225 | |||||||||||||||||
| Voltage Inspection Instrument | 8 workstations | 8 workstations | 16 workstations | 16 workstations | 16 workstations | |||||||||||||||||
| Temperature Inspection | 8 workstations | 8 workstations | 16 workstations | 16 workstations | 16 workstations | |||||||||||||||||
| Measure battery/stack model | Compatible 5×5/10×10/16×16 cm Single battery | Compatible with a single battery, 100 W/500 W short stack | Compatible 500 W/1 kW fuel cell stack | Compatible 1 kW/2 kW fuel cell stack | Compatible 2 kW/5 kW fuel cell stack | |||||||||||||||||
| Hydrogen production via methane or methanol reforming | / | Optional configuration | Optional configuration | Optional configuration | Optional configuration | |||||||||||||||||
| Test furnace | Servo‑assisted pressurization, vertical alignment; 25–1000°C, pressure range 0–300 kg. | |||||||||||||||||||||
| Test Item | Current–voltage curve testing, constant‑voltage/constant‑current durability testing, variable current/voltage dynamic testing, gas‑tightness testing, and reversible power generation/electrolysis testing, among others. | |||||||||||||||||||||
| Safety Management Unit | Safety protection categories: over/under temperature, over/under gas pressure, excessive pressure differential, gas supply abnormality, hazardous gas leakage, overcurrent, and others. | |||||||||||||||||||||
| Protective measures: EX‑rated explosion-proof enclosure, circuit fuses, emergency system braking, gas supply shut-off, and electric furnace cooling. | ||||||||||||||||||||||
| Optional Components | Humidifiers, hydrogen production systems (methanol/natural gas reforming, water electrolysis), and exhaust gas analysis equipment (gas chromatographs, gas chromatography–mass spectrometers, soap‑film flow meters, etc.) Electrochemical workstation, current interruption method, air compressor | |||||||||||||||||||||