The test system is designed to evaluate the electrical performance of solid oxide fuel cells and stacks. It features gas‑line control, data acquisition, intelligent temperature regulation, and fuel‑gas leak safety alarms, enabling real-time monitoring of performance under various operating modes, including constant current, constant voltage, and constant power.
Key product features:
1. Equipped with multiple gas supply and humidification modules to simulate various fuel‑testing requirements;
2. Customize test plans based on customer requirements and provide SOFC/SOEC testing skills training.
3. High measurement and control accuracy, with test data management capabilities;
4. Equipped as standard with a positive-pressure explosion-proof control cabinet, the design incorporates proactive safety principles to eliminate potential hazards at their source.
| Test system parameters | ||||||||||||||||||||||
| Device model | HBSOC-100 | HBSOC-500 | HBSOC-1000 | HBSOC-2000 | HBSOC-5000 | Note | ||||||||||||||||
| Test power | 100W | 500W | 1 kW | 2 kW | 5kW | |||||||||||||||||
| Cathode gas type | Air | Air | Air | Air | Air | |||||||||||||||||
| Cathode gas flow rate (SLM) | 0.2-20 | 0.5-50 | 1-100 | 2-200 | 5-450 | |||||||||||||||||
| Cathode gas control accuracy | ±1%FS | ±1%FS | ±1%FS | ±1%FS | ±1%FS | |||||||||||||||||
| Anode gas type | H | CH | co | Carbon dioxide | N₂ | H | CH | co | co2 | N₂ | H₂ | CO | Carbon dioxide | N₂ | H₂ | Carbon dioxide | N₂ | H₂ | Carbon dioxide | N₂ | Anode gas type Customizable |
|
| Anode gas flow rate (SLM) | 01-5 | 01-2 | 01-5 | 01-5 | 00-5 | 0.2-20 | 00-5 | 02-20 | 00-5 | 02-20 | 0.2-20 | 0.2-20c | 0.2-20 | 02-20 | 0.5-50 | 0.5-50 | 0.2-20 | 2-150 | 0.5-50 | 0.5-50 | ||
| Anode gas control accuracy | ±1%FS | ±1%FS | ±1%F.S | ±1%FS | ±1%FS | |||||||||||||||||
| Gasification water flow rate (SCCM) | 00-5 | 00-5 | 0-20 | 0-50 | 0-50 | |||||||||||||||||
| Steam control accuracy | ±1% | ±1% | ±1% | ±1% | ±1% | |||||||||||||||||
| Steam outlet temperature (°C) | 200-280 | 200-280 | 200-280 | 200-280 | 200-280 | |||||||||||||||||
| Discharge Module (SOFC) |
Discharge Voltage (V) | 0-120 | 0-120 | 0-120 | 0-150 | 0-150 | ||||||||||||||||
| Discharge current (A) | 0-120 | 0-120 | 0-240 | 0-200 | 0-600 | |||||||||||||||||
| Electrolysis Module (SOEC) |
Electrolysis voltage (V) | 0-32 | 0-80 | 0-160 | 0-80 | 0-300 | ||||||||||||||||
| Electrolytic current (A) | 0-110 | 0-40 | 0-40 | 0-150 | 0-225 | |||||||||||||||||
| Voltage Inspection Instrument | 8 workstations | 8 workstations | 16 workstations | 16 workstations | 16 workstations | |||||||||||||||||
| Temperature Inspection | 8 workstations | 8 workstations | 16 workstations | 16 workstations | 16 workstations | |||||||||||||||||
| Measure battery/stack model | Compatible 5×5/10×10/16×16 cm Single battery |
Compatible with a single battery, 100 W500 W short stack |
Compatible 500 W/1 kW fuel cell stack |
Compatible 1 kW/2 kW fuel cell stack |
Compatible 2 kW/5 kW fuel cell stack |
|||||||||||||||||
| Hydrogen production via methane or methanol reforming | / | Optional equipment | Optional equipment | Optional equipment | Optional equipment | |||||||||||||||||
| Test furnace | Servo pressurization, vertical alignment: 25–1000°C, pressure range 0–300 kg | |||||||||||||||||||||
| Test Item | Current–voltage curve testing, constant‑voltage/constant‑current durability testing, variable current/voltage dynamic testing, airtightness testing, and reversible power generation/electrolysis testing, among others. | |||||||||||||||||||||
| Safety Management Unit | Safety protection categories: over/under temperature, gas over/under pressure, excessive pressure differential, gas supply abnormality, hazardous gas leakage, overcurrent, and others. | |||||||||||||||||||||
| Protective measures: explosion-proof enclosure, circuit fuses, emergency system braking, gas supply shut-off, and electric furnace cooling. | ||||||||||||||||||||||
| Optional Components | Humidifiers, hydrogen production systems (methanol/natural gas reforming, water electrolysis), and exhaust gas analysis equipment (gas chromatographs, gas mass spectrometers, soap‑film flow meters, etc.), Electrochemical workstation, current interruption method, air compressor |
|||||||||||||||||||||
Keywords:
Explosion-proof testing system
Message