Product Description
Introduction to the 60 kW Range-Extender Assembly
The 60 kW range extender is a primary power‑generation system comprising a 2.0‑liter naturally aspirated gasoline or gas engine, an integrated starter‑generator (ISG), and a power‑follow controller (RECU), primarily responsible for converting fuel into electrical energy.
Main application markets;
1. The range extender serves as the primary source of electrical power, supplying drive energy to light trucks, buses, yachts, construction machinery, and more, while also charging the traction battery. The traction battery acts as an auxiliary power source. Vehicles equipped with this range extender deliver superior performance and fuel efficiency.
2. Centered on a range extender as the primary power source and paired with an energy‑storage battery, this “fuel‑battery” hybrid power system replaces conventional diesel generator sets, meeting the diverse power‑supply needs of remote islands, field sites, construction zones, base stations, and other locations.
3. As the primary power supply system, the RECU employs a power‑following control strategy, ensuring that the follower operates continuously within the optimal fuel consumption range and significantly enhancing fuel utilization efficiency.
Generator Efficiency MAP Chart

Schematic diagrams of gas consumption rates and efficiencies under various operating conditions.

4. Test Conclusion
In this test, the 60 kW range‑extender assembly underwent CAN communication debugging, start‑up calibration, operating‑point calibration, fuel‑efficiency testing, and diagnostic‑module calibration. The following conclusions were drawn:
● CAN communication is functioning properly, and the RECU, ECU, and GCU can all send and receive messages without issue.
● The range extender starts quickly and, once started, smoothly transitions to idle; the entire process from startup to stable idling takes approximately 3 seconds.
● After tuning, the range extender has been verified to operate stably under all operating conditions, with speed fluctuations meeting the design specifications.
● Economic performance test data: At a power output of 30–60 kW, the gas consumption rate is below 220 g/kW·h, with a minimum specific fuel consumption of 208.00 g/kW·h at 50 kW; the system’s peak efficiency reaches 95.37%.
● Note: With CNG priced at 4.1 yuan/kg, the minimum gas consumption per kWh is calculated as 0.85 yuan/kWh, while the gas consumption at the rated power point is 0.87 yuan/kWh.
● With the calibrated diagnostic module enabled, the range extender can promptly respond to conditions such as overheating, overload, and electrical faults.
Introduction to the 90 kW Range-Extender Assembly
The 90 kW range extender is a primary power‑generation unit comprising a 2.9‑liter natural‑gas engine, an integrated starter‑generator (ISG), and a power‑follow controller (RECU), primarily responsible for converting fuel into electrical energy.
Main application markets;
1. The range extender serves as the primary source of electrical power, supplying drive energy to medium-duty trucks, buses, marine vessels, and construction machinery, while also charging the traction battery. The traction battery acts as an auxiliary power source. Vehicles equipped with this range extender deliver high performance and excellent fuel efficiency.
2. Centered on a range extender as the primary power source and paired with an energy‑storage battery, this “fuel‑battery” hybrid power system replaces conventional diesel generator sets, meeting the diverse power‑supply needs of remote islands, field sites, construction zones, base stations, and other locations.
3. As the primary power supply system, the RECU employs a power‑following control strategy, ensuring that the follower operates continuously within the optimal fuel consumption range and significantly enhancing fuel utilization efficiency.
Generator Efficiency MAP Chart

Schematic diagrams of gas consumption rates and efficiencies under various operating conditions.

4. Test Conclusion
In this test, the 90 kW range‑extender assembly underwent CAN communication debugging, start‑up calibration, operating‑condition point calibration, fuel‑efficiency testing, and diagnostic‑module calibration. The following conclusions were drawn:
● CAN communication is functioning properly, and the RECU, ECU, and GCU can all send and receive messages without issue.
● The range extender starts quickly and, once started, smoothly transitions to idle; the entire process from startup to stable idling takes approximately 2 seconds.
● After tuning, the range extender has been verified to operate stably under all operating conditions, with speed fluctuations meeting the design specifications.
● Economic performance test data: At a power output of 40–90 kW, the specific gas consumption is below 215.00 g/kW·h, with the lowest specific consumption recorded at 207.14 g/kW·h at 70 kW; the system’s peak efficiency reaches 95.64%.
● Note: With CNG priced at RMB 4.1 per kg, the minimum gas consumption per kWh is calculated as RMB 0.85/kWh, while at full‑power operation, the gas consumption rises to RMB 0.86/kWh.
● With the calibrated diagnostic module enabled, the range extender can promptly respond to conditions such as overheating, overload, and electrical faults.
Introduction to the 50 kW Methanol Power Generation System
The 50 kW range extender is a primary power‑generation unit comprising a 1.8‑liter methanol engine, an integrated starter‑generator (ISG), and a power‑follow controller (RECU), primarily responsible for converting fuel into electrical energy.
Main application markets;
1. The range extender serves as the primary source of electrical power, supplying drive energy to light trucks, small buses, yachts, construction machinery, and more, while also charging the traction battery. The traction battery acts as an auxiliary power source. Vehicles equipped with this range extender exhibit excellent performance and fuel efficiency.
2. Centering on a generator set as the primary power source and integrating energy storage batteries, a “fuel‑storage” hybrid power system is established to replace conventional diesel generator sets, meeting the power supply needs of diverse locations such as isolated islands, remote field sites, construction zones, and base stations.
3. As the primary power supply system, the RECU employs a power‑following control strategy, ensuring that the follower operates continuously within the optimal fuel consumption range and significantly enhancing fuel utilization efficiency.
Engine performance curve chart

Methanol fuel consumption

| Technical Parameters of Methanol-Based DC Generator Sets for Grid Integration | ||
| Engine brand | 1.8L methanol DC generator set grid connection | |
| Generating power | Rated 45 kW | |
| Displacement | 1.8L | |
| Rated speed | 3000rpm | |
| Structural form | Inline-four engine | |
| Fuel system | Inlet spray injection | |
| Fuel Type | M100 | |
| Fuel consumption | 465/kWh (M100 methanol) | |
| Intake method | Naturally aspirated | |
| Voltage platform | DC400V | DC600V |
| Startup method | Direct start of DC motor; extreme cold: PTC cold-start heating | |
| Cooling method | Closed-loop water tank cooling | |
| Unit dimensions | Length × Width × Height: 717*648*669 |
Length × Width × Height: 705*648*669 |
| Minimum ambient temperature | -35℃ | |