DT New Energy Exclusive Interview with “Hydrogen Bang Technology”: Pioneering a SOFC stack testing device with “universal characteristics,” precisely identifying the stack’s “operating window” and “operating boundaries.”
Release Date:
2026-05-09
At the critical stage when solid oxide fuel cells (SOFCs) are transitioning from the laboratory to industrial-scale deployment, the evaluation of stack performance and system integration capabilities have emerged as the core bottlenecks hindering technological implementation. Recently, DT New Energy visited Zhejiang Hydrogen Bang Technology Co., Ltd. (hereafter referred to as “Hydrogen Bang Technology”) and conducted an exclusive interview with the company’s technical team, focusing on two products unveiled at the 6th Solid Oxide Fuel Cell Technology Development and Industry Forum: a “SOC stack assembly with internal‑combustion‑engine‑like characteristics” and a “universal test rig for fuel cell stacks and stack assemblies.”
At the critical stage when solid oxide fuel cells (SOFCs) are transitioning from the laboratory to industrial-scale deployment, the evaluation of stack performance and system integration capabilities have emerged as the core bottlenecks hindering technological implementation. Recently, DT New Energy visited Zhejiang Hydrogen Bang Technology Co., Ltd. (hereafter referred to as “Hydrogen Bang Technology”) and conducted an exclusive interview with the company’s technical team, focusing on two products unveiled at the Sixth Solid Oxide Fuel Cell Technology Development and Industry Forum: a “SOC stack assembly with internal‑combustion‑engine‑like characteristics” and a “universal‑characteristic testing device for fuel cell stacks and stack assemblies.”

(Image source: Hydrogen Bang Technology)
Drawing on the “universal characteristic curve” concept from the internal combustion engine field, Hydrogen Bang Technology has pioneered the development of a SOFC stack universal‑characteristic‑curve testing system tailored for practical engineering applications. This equipment enables automated, high‑precision identification of the stack’s “operating window” and “operating boundaries,” covering temperature limits, mechanical load limits, and safety thresholds, while generating comprehensive datasets that include external reforming data, internal reforming data, fuel‑gas sweep data, and electrical‑thermal coupling data.
By establishing high‑efficiency operating zones and health‑optimization zones, this device facilitates the adaptation of stack components, power density matching, thermal capacity alignment, and insulation compatibility, while also defining a set of state transitions. This enhances both the system’s structural integrity and operational reliability. Hydrogen Bang Technology states that this testing framework not only reduces the stack’s initial construction and maintenance costs but also achieves the engineering objectives of easy power integration, straightforward component matching, and compact volume coordination, thereby providing critical technical support for the efficient, safe, and long‑term operation of SOC stack assemblies.

Framework Diagram of the “Universal Characteristics” Testing System for SOFC Stacks Aimed at Engineering Implementation
(Image source: Hydrogen Bang Technology)
01 Breaking the limitations of traditional testing: from static I‑V curves to dynamic universal characteristics
The technical director of Hydrogen Bang Technology pointed out that conventional SOFC stack testing typically relies on I–V curves, but this approach is fundamentally a static test—measuring the stack’s electrical performance under fixed conditions such as temperature, fuel flow rate, and air flow rate. While effective in an “ideal, stable laboratory environment,” this method struggles to capture the stack’s true behavior under real-world operating‑condition variations.
“Conventional I–V curves cannot identify the high-efficiency operating region, nor can they reveal the low‑efficiency zone where concentration polarization becomes severe at high current densities. More critically, they fail to provide effective guidance for parameter matching of the system’s BOP (balance‑of‑plant) components,” the lead researcher stated. “The stack exhibits vastly different performance under varying temperatures, fuel flow rates, and air‑to‑fuel ratios, rendering static testing inadequate for system‑level development needs.”
02 Drawing Inspiration from the Universal Characteristics of Internal Combustion Engines
The Hydrogen Bang Technology team has creatively adopted the well-established “universal characteristic curve” testing concept from the internal combustion engine field. By plotting multiple parameters—such as engine speed, mean effective pressure, fuel consumption rate, and efficiency—on a single graph, the team generates lines of constant fuel consumption and constant efficiency, thereby clearly defining the optimal operating region.
By analogy to an SOFC stack, Hydrogen邦 plots the fuel flow rate (or its equivalent current reference) on the vertical axis and the current density (or the load‑dependent single‑cell voltage) on the horizontal axis, thereby generating a comprehensive performance characteristic curve that encompasses multiple parameters such as temperature, power generation efficiency, and cell voltage.

Universal Characteristic Curve of an SOFC Stack
(Image source: Hydrogen Bang Technology)
030,000–characteristic testing equipment: automatically identifies the working window and working boundaries.
Based on this concept, Hydrogen Bang Technology has successfully developed China’s first set of universal characteristic testing equipment for SOFC stacks. This equipment can automatically perform the following key tasks:
Automatically test the “operating window” of a fuel cell stack or stack assembly—namely, the optimal operating region that satisfies multiple constraints, including electrical efficiency, voltage decay, and thermal‑stress safety.
Clearly define “operational boundaries”: Identify the limit‑condition boundaries associated with seal failure, macroscopic parameters, thermal‑stress cracking, and exacerbated concentration polarization, thereby preventing the stack from operating in hazardous regions.
Multi-parameter collaborative scanning: synchronously controls variables such as temperature, fuel flow rate, air flow rate, and current density, dynamically acquiring the stack’s performance response across the entire operating range.

SOFC Stack Universal Characteristic Testing Equipment
(Image source: Hydrogen Bang Technology)
04 Compared with conventional SOFC testing equipment, the advantages are evident.
Compared with conventional SOFC testing equipment, Hydrogen Bang Technology’s universal characteristic testing system offers the following distinct advantages:
| Dimension |
Conventional SOFC test equipment |
Hydrogen Bang Universal Property Testing Equipment |
| Testing method |
Static, single operating point |
Dynamic, multi-parameter coupled scanning |
| Result Presentation |
Single I-V curve |
Multidimensional universal characteristic curve diagram (temperature, efficiency, voltage, current, flow rate) |
| Run Area Identification |
Unable to distinguish between high- and low-efficiency zones. |
Clearly delineate the high-efficiency zone, the low-efficiency zone, and the danger boundary. |
| System matching capability |
Unable to provide guidance on BOP selection. |
It can provide full‑range operating‑condition parameter references for air compressors, heat exchangers, and fuel supply systems. |
| Aging and Repetitiveness |
Difficult to identify the degradation mechanism. |
It can continuously monitor drift in the fuel cell stack’s operating window and identify degradation patterns. |
Source: Hydrogen Bang Technology
05 Accelerating the Integration and Commercialization of SOFC Systems
Hydrogen Bang Technology stated that the launch of its universal performance‑testing equipment has not only enhanced the efficiency and depth of fuel‑cell stack development but has also provided SOFC system integrators with quantifiable stack‑operating boundary maps. Armed with these insights, system engineers can fine‑tune BOP parameters, preventing both over‑design and mismatch, thereby significantly shortening the system development cycle and mitigating risks.
“We hope this equipment will become a foundational tool for the SOFC industry—much like the universal characteristic test bench in the internal‑combustion‑engine sector—helping to drive the entire value chain toward standardization, systematization, and intelligentization,” the project leader concluded. At present, Hydrogen Bang Technology has supplied multiple test rigs and related services to numerous domestic SOFC stack and system manufacturers, while continuing to advance the development of higher‑power, higher‑temperature stack‑testing platforms.